Searched for "40141616"
Honeywell Home's 802360JA/U is a 24-Volt replacement motor for V8043/44 zone valve. It is the ideal choice for contractors because of its easy installation. When it comes to top quality, Honeywell Home's zone valves can be trusted.
- Valve includes motor mounting screw and lead connectors
- Used with V8043A, V8043E, and V8043F
- Frequency-50 Hz, 60 Hz
- 24-Volt electrical connections
- Electrical connections - 6 in. leads; 152 mm leads
Danfoss Aveo Sensors, Electronic, Sensor type. Easy To Use. Thermostatic Radiator Valve. Built in Tamper Proof. 015G4290. Mfg #015G4290
- Easy To Use
- Thermostatic Radiator Valve
- Built in Tamper Proof
- 015G4290
Nibco Copper Coupling. Mfg #9020400
- 0.75" Inlet
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- Without Stop
Danfoss -- Straight Valve Body. For Ra2000 Units. Connection: 3/4" Npt.
Nibco ACR Copper Reducer Bushing
0.88 X 0.75" Od
NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
Mfg #108286
- 0.88 X 0.75" Od
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- ACR Copper Reducer Bushing
Nibco® ACR Copper 90° Long Radius Elbow
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- Mfg #9080400
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- with stop
Nibco® ACR Copper 90° Long Radius Elbow C x C
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- Mfg #108283
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- with stop
Nibco ACR Copper 45° Elbow
0.88" Od
Dezincification Resistant
NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
Mfg #9042900
- 0.88" Od
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems
- Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
Nibco ACR Copper 90° Elbow
0.88" Od
Dezincification Resistant
NFPA 99 Health Care Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
Mfg #9055600
- 0.88" Od
- Dezincification Resistant
- NFPA 99 Health Care Facilities Gas And Vacuum Systems
- Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
AM-1 series adjusts, maintains and limits the hot water temperature settings to provide comfort and protect equipment at home. Designed to prevent scalding water and legionella bacteria growth by storing water at 140 degree F and higher. Delivers safe and comfortable water temperatures out of the faucet at 120 degree F.
- Offers constant water temperature under changing operating conditions
- Temperature is limited at any point and if cold water supply is interrupted, flow reduction occurs in seconds
- Designed for easy maintenance and Teflon coating prevents mineral build-up and extends life
- Provides reliable performance at minimum flow of 05 GPM and proportional valve for simultaneous control of hot and cold
- Features dual purpose mixing or diverting values
- Lead free products have products numbers end in LF
- Available temperature gauge adapter in lead-free brass material with EPDM O-ring
- Maximum safe operating pressure (psi)150 psi
- Minimum flow rate (gpm) 0.5 GPM
- Includes check valves on hot and cold ports
The GoldTop offers a convenient, one-fits-all concept, to stock one vent for all your venting needs, between 1 and 150 psi systems. Honeywell's revolutionary patented fulcrum design offers a venting rate of 3-4 times that of other products. Used in Residential or commercial heating and cooling systems.
- Maximum safe operating pressure (psi) 150 psi
- Operating temperature range (F)240 degree F
- Male NPT connection
- Patent no. 5,988,201
- Light weight
- Proven durability
- Easy to install
- No clog vent
- 360 degree adjustable collar ring for installation flexibility
- Stainless steel concentrator which eliminates gurgling noise
Automatic Air Vent purges air from high pressure mains and equipment in hot or cold closed water systems. Includes removable float/valve assembly for easy servicing. Not for use in steam systems.
- Designed with the higher capacity normally required by North American heating systems
- Valve seat disc, which is made of resilient material (EPDM), ensures tight shutoff on steam or hot water systems
- Controls include sensor, set-point dial and valve actuator; components may be integral or connected by capillary tubes
- Require no electrical connections
- Body, cover and float made of thermoplastics
- Used in residential or commercial heating and cooling systems
- NBR seat disc and O-ring
- Internal parts made of corrosion resistant and chemical resistant materials
- For use with hydronic systems that may contain concentrations of propylene or etheylene glycol
- Built-in shut-off valve and leakage guard
- 1" NPT PRV Internal DOT
- 375PSI
- With cap
*MUST BE INSTALLED BY TRAINED PERSONNEL IN ACCORDANCE WITH NFPA 58 & 54 STATE AND LOCAL CODES
Danfoss Aveo Tamperproof Sensor
- Easy To Use
- Thermostatic Radiator Valve
- Mfg #015G4240
- Easy To Use
- Thermostatic Radiator Valve
- Tamperproof
- Danfoss Aveo
Nibco ACR Copper Coupling. Mfg #9001003
- 0.38" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
Danfoss -- Straight Valve Body. For Ra2000 Units. Connection: 1/2" Npt.
Zone Panel for conventional and heat pump applications. Intuitive Installer setup. Easy-to-follow, digital display uses real language to guide installer through four easy steps.
- Standard checkout procedure
- Robust push terminals
- Common-Sense LEDs
- Clean, professional installation
Danfoss Part # 013G8042 1/2" Or 013G8044 3/4" Solder Union Straight Valve Body For Ra2000 Units. Conforms To Ansi/Ashrae Standard 102-1983
Taco Switching Relays combine clearly labeled PC board layouts with advanced features that allow for total system customization. External indicator lights provide instant diagnostic feedback, making a snap of service calls or new installation start-ups. All switching relays are UL Listed, are compatible with conventional and programmable thermostats.
- Compact design
- UL and CSA approved
- 3-year warranty
- Fuse protected
- Simplified wiring for ease of installation
- Premium sealed relays
This Type 1 ACME valve (CGA791) is intended for DOT cylinders with 40 pounds LPG capacity. This valve has a vapor service outlet, relief valve, captive fixed liquid level gauge, and an overfill prevention device (OPD). The brass safety cage surrounds critical welds, providing additional protection to components for long-term operational performance.
- Rapid purging and filling with over one million BTU withdrawal capacity
- Tri-lobular one-piece forged aluminum handwheel
- Double o-ring stem seal for improved leak resistance
- Pre-applied sealant
- Quality o-ring check valve seat; opens only with positive seal
- Cylinder capacity: 40 lbs
- Container Connection: 3/4" 14 NGT
- Outlet Connection: Type 1 ACME and POL
- Relief Setting: 375 PSIG
- Dip Tube: 6.4"
- Indicates the maximum filling level
- 1/4" MNPT container connection
- 5.6" dip tube length
*MUST BE INSTALLED BY TRAINED PERSONNEL IN ACCORDANCE WITH NFPA 58 & 54 STATE AND LOCAL CODES
- Leak resistant design
- Double O-ring stem seal
- Tamper proof design
- Sturdy forged brass handle
- Static seat disc
- Recessed excess flow valve
- Normal application forklifts
- 3/4" MNPT cylinder x 3/8" MNPT outlet
- 2.6 gpm excess flow closing
*MUST BE INSTALLED BY TRAINED PERSONNEL IN ACCORDANCE WITH NFPA 58 & 54 STATE AND LOCAL CODES
Honeywell AMX series Direct Connect reduces water heater installation time as the cold and hot port position eliminates the need for typical elbows and tees. New design requires a maximum of just two sweat connections. Requires fewer parts than previous models.
- Designed to be directly installed on water heater hot outlet port
- Offers constant water temperature under changing operating conditions
- Temperature is adjustable using 3/16 allen wrench and if cold water supply is interrupted, flow reduction occurs in seconds
- Features brass/stainless construction and Teflon coated of wear surfaces
- Alternate hot port bypasses hot water directly from the tank to non-mixed temperature applications
- Maximum safe operating pressure 150 psi
- Operating temperature range (F)33 degree F to 80 degree F (cold water inlet); 100 degree F to 212 degree F (hot water inlet)
- Minimum flow rate (GPM) 0.25 GPM; recirculation port: 1/2 in. NPT; alternate hot port: 1/2 in. NPT
- Fluid temperature (F) mixed water supply--100 degree F to 145 degree F
- Capacity 2.3 Cv
AM-1 series adjusts, maintains, and limits the hot water temperature settings to provide comfort and protect equipment at home. Designed to prevent scalding water and legionella bacteria growth by storing water at 140 degree F and higher. Delivers safe and comfortable water temperatures out of the faucet at 120 degree F.
- Offers constant water temperature under changing operating conditions
- Temperature is limited at any point and if cold water supply is interrupted, flow reduction occurs in seconds
- Designed for easy maintenance and Teflon coating prevents mineral build-up and extends life
- Provides reliable performance at minimum flow of 05 GPM and proportional valve for simultaneous control of hot and cold
- Features dual purpose mixing or diverting values
- Lead free products have products numbers end in LF
- Available temperature gauge adapter in lead-free brass material with EPDM O-ring
- Maximum safe operating pressure (psi)150 psi
- Minimum flow rate (GPM) 0.5 GPM
- Includes check valves on hot and cold ports