Searched for "40141616"
Honeywell Home's 802360JA/U is a 24-Volt replacement motor for V8043/44 zone valve. It is the ideal choice for contractors because of its easy installation. When it comes to top quality, Honeywell Home's zone valves can be trusted.
- Valve includes motor mounting screw and lead connectors
- Used with V8043A, V8043E, and V8043F
- Frequency-50 Hz, 60 Hz
- 24-Volt electrical connections
- Electrical connections - 6 in. leads; 152 mm leads
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
This 1/2 in. high capacity feed water pressure regulator is for use in commercial and residential hydronic heating systems to fill the boiler and piping system with water, and to maintain water pressure in the system at all times. It also provides make-up water to the system in the event of system leaks. It consists of a bronze body with union threaded inlet and NPT threaded outlet connections, a tight seating check valve, purge lever for manual purging, and a stainless steel strainer. It has high capacity performance and a simplified servicing design. It is suitable for use in the boiler feed lines of hydronic heating systems. The maximum pressure is 100 psi (6.9 bar).
- Tight seating check valve
- Purge lever
- High capacity
- Stainless steel strainer
- Union threaded inlet connection
- Used to maintain water pressure in commercial and residential hydronic heating systems at all times
- Provides make-up water to the system in the event of system leaks
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
AM-1 series adjusts, maintains, and limits the hot water temperature settings to provide comfort and protect equipment at home. Designed to prevent scalding water and legionella bacteria growth by storing water at 140 degree F and higher. Delivers safe and comfortable water temperatures out of the faucet at 120 degree F.
- Offers constant water temperature under changing operating conditions
- Temperature is limited at any point and if cold water supply is interrupted, flow reduction occurs in seconds
- Designed for easy maintenance and Teflon coating prevents mineral build-up and extends life
- Provides reliable performance at minimum flow of 05 GPM and proportional valve for simultaneous control of hot and cold
- Features dual purpose mixing or diverting values
- Lead free products have products numbers end in LF
- Available temperature gauge adapter in lead-free brass material with EPDM O-ring
- Maximum safe operating pressure (psi)150 psi
- Minimum flow rate (GPM) 0.5 GPM
- Includes check valves on hot and cold ports
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. For use in hydronic controls. Press-connect fittings.
- All models may be installed without disassembling the valve
- Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure
- Valve returns to automatic position when power is restored
- Compact construction for easy installation
2-Way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
Honeywell AMX series Direct Connect reduces water heater installation time as the cold and hot port position eliminates the need for typical elbows and tees. New design requires a maximum of just two sweat connections. Requires fewer parts than previous models.
- Designed to be directly installed on water heater hot outlet port
- Offers constant water temperature under changing operating conditions
- Temperature is adjustable using 3/16 allen wrench and if cold water supply is interrupted, flow reduction occurs in seconds
- Features brass/stainless construction and Teflon coated of wear surfaces
- Used in domestic hot water
- Hot inlet - female NPT; mixed outlet - male NPT
- Mixed water supply--100 degree F to 145 degree F
- Minimum flow rate 0.25 GPM; recirculation port: 1/2 in. NPT; alternate hot port: 1/2 in. NPT
- 2.3 CV capacity
- Maximum safe operating pressure 150 psi
2-Way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
Watts 1/2 IN Lead Free Anti-Siphon Pressure Vacuum Breaker Backflow Preventer Includes A Freeze Sensor For Use With Sentryplus Alert Technology To Signal Facility Personnel When Temperature Nears And Reaches The Freezing Point Available freeze sensor connection kit to activate a monitoring system that trigger alerts for low and freezing temperatures Lead free construction Replaceable seat Female NPT inlet and outlet with quarter turn shutoffs Easy internal access Mfg #T792010
- Includes A Freeze Sensor For Use With Sentryplus Alert Technology To Signal Facility Personnel When Temperature Nears And Reaches The Freezing Point
- Available freeze sensor connection kit to activate a monitoring system that trigger alerts for low and freezing temperatures
- Lead free construction
- Replaceable seat
Nibco ACR Copper 90degree Long Radius Elbow
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- Mfg #9080400
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- with stop
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Patent no. 5,988,201
- Light weight
- Proven durability
- Easy to install
- No clog vent
- 360 degree adjustable collar ring for installation flexibility
- Stainless steel concentrator which eliminates gurgling noise
Watts 3/4 IN 374A Iron Boiler Pressure Relief Valve, 30 psi, Forged Brass Inlet Features A Flood Sensor With Sentryplus Alert Technology To Detect Excessive Water Discharges From The Relief Valve Requires purchase of activation kit to activate sensor Iron body with forged bronze inlet 550,000 BTU/hr rating Non-metallic disc-to-metal seating Set pressure 30 psi Mfg #F358553
- Features A Flood Sensor With Sentryplus Alert Technology To Detect Excessive Water Discharges From The Relief Valve
- Requires purchase of activation kit to activate sensor
- Iron body with forged bronze inlet
- 550,000 BTU/hr rating
- Minute Man Eye anchors are commonly used for securing small planes, vineyard trellises, storage sheds, tents, orchard and nursery trees, swing sets, clothes lines, fences, retaining walls, radio antennas, small windmills, floating docks, and pet restraint.
- All eye anchors are manufactured from steel that conforms to ASTM A-36 M1020 standards. Holding strength is based on clay soils which are of hard to medium density. The holding strength is reduced in softer less dense soils and sandy soils. To ensure maximum holding strength, anchor must be installed to full depth with the bottom of eyelet at ground level.
- Anchor eyelets are always weld closed, eyelets can be left open upon request of the customer.
- Leak resistant design
- Double O-ring stem seal
- Tamper proof design
- Sturdy forged brass handle
- Static seat disc
- Recessed excess flow valve
- Normal application forklifts
- 3/4" MNPT cylinder x 3/8" MNPT outlet
- 2.6 gpm excess flow closing
*MUST BE INSTALLED BY TRAINED PERSONNEL IN ACCORDANCE WITH NFPA 58 & 54 STATE AND LOCAL CODES
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
- 4 in 1 alternative replaces a ball valve and 2 tee fittings and 1 boiler drain
- Quickly connect entire system to cold water feed
- Easily install, isolate, drain and replace any expansion tank
- Pressure rated at 600 WOG
- 1/2" FIP x MIP x FIP x HOSE
Nibco ACR Copper Coupling. Mfg #9001003
- 0.38" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
- Double back check construction - soft seated upper back check and metal to metal lower back check
- Allows low flow resistance, prolonging pump and hose life
- One piece body design
- For use in domestic tanks
- 1-3/4"M. Acme line
- 13 gpm filling
*MUST BE INSTALLED BY TRAINED PERSONNEL IN ACCORDANCE WITH NFPA 58 & 54 STATE AND LOCAL CODES
- Has only the poppet and part of the body outside the tank connection
- Internal guiding to prevent being jammed by foreign material
- Adjustment nut is located on the end of the stem inside the tank to prevent tampering
- Rain caps included
- ASME container
- 250 psig discharge setting
- 4312 Flow Capacity UL
*MUST BE INSTALLED BY TRAINED PERSONNEL IN ACCORDANCE WITH NFPA 58 & 54 STATE AND LOCAL CODES
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Electrical connections (in.) screw terminal block
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
- Valve designed for cycling (not constantly powered on) applications
- Quick fit pushbutton powerhead makes it easy to remove for service
- Innovative motor technology offers silent operation, water hammer resist and longer life
- Series 5000 replacement powerhead is backward compatible with series 1000 zone valves
- Easy to install and operate
Zone Panel for conventional and heat pump applications. Intuitive Installer setup. Easy-to-follow, digital display uses real language to guide installer through four easy steps.
- Standard checkout procedure
- Robust push terminals
- Common-Sense LEDs
- Clean, professional installation
This Type 1 ACME valve (CGA791) is intended for DOT cylinders with 40 pounds LPG capacity. This valve has a vapor service outlet, relief valve, captive fixed liquid level gauge, and an overfill prevention device (OPD). The brass safety cage surrounds critical welds, providing additional protection to components for long-term operational performance.
- Rapid purging and filling with over one million BTU withdrawal capacity
- Tri-lobular one-piece forged aluminum handwheel
- Double o-ring stem seal for improved leak resistance
- Pre-applied sealant
- Quality o-ring check valve seat; opens only with positive seal
- Cylinder capacity: 40 lbs
- Container Connection: 3/4" 14 NGT
- Outlet Connection: Type 1 ACME and POL
- Relief Setting: 375 PSIG
- Dip Tube: 6.4"