2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Patent no. 5,988,201
- Light weight
- Proven durability
- Easy to install
- No clog vent
- 360 degree adjustable collar ring for installation flexibility
- Stainless steel concentrator which eliminates gurgling noise
1/8 in. IPS male thread connection. Use screwdriver or coin to operate. 5 years warranty against defect.
- Air vent
- Hot water
- Valve only
- Nickel plated
- Silver
- Specifications
- Safety
- 125 psi
- Fits 1/8 in. threads
- Meets ASME standards
Danfoss -- Straight Valve Body. For Ra2000 Units. Connection: 1/2" Npt.
Dunham-Bush Low Pressure Steam Trap 3/4"
The GoldTop offers a convenient, one-fits-all concept, to stock one vent for all your venting needs, between 1 and 150 psi systems. Honeywell's revolutionary patented fulcrum design offers a venting rate of 3-4 times that of other products. Used in Residential or commercial heating and cooling systems.
- Maximum safe operating pressure (psi) 150 psi
- Operating temperature range (F)240 degree F
- Male NPT connection
- Patent no. 5,988,201
- Light weight
- Proven durability
- Easy to install
- No clog vent
- 360 degree adjustable collar ring for installation flexibility
- Stainless steel concentrator which eliminates gurgling noise
- 1/2"
- Replacement interiors (Type "A" Cage Units) for: B-1 (Integral Bellows removable seat)
- Manufacturer number 4270
- Renew worn out thermostatic steam traps the easy and efficient way by installing Barnes & Jones cage units in your present trap bodies. Unit contains all working parts, elements and seat in one compact unit, correctly and permanently calibrated before leaving the factory. Easy to install; ready to drop into your trap with no tapping or machining necessary
Automatic Air Vent purges air from high pressure mains and equipment in hot or cold closed water systems. Includes removable float/valve assembly for easy servicing. Not for use in steam systems.
- Designed with the higher capacity normally required by North American heating systems
- Valve seat disc, which is made of resilient material (EPDM), ensures tight shutoff on steam or hot water systems
- Controls include sensor, set-point dial and valve actuator; components may be integral or connected by capillary tubes
- Require no electrical connections
- Body, cover and float made of thermoplastics
- Used in residential or commercial heating and cooling systems
- NBR seat disc and O-ring
- Internal parts made of corrosion resistant and chemical resistant materials
- For use with hydronic systems that may contain concentrations of propylene or etheylene glycol
- Built-in shut-off valve and leakage guard
Danfoss Part # 013G8042 1/2" Or 013G8044 3/4" Solder Union Straight Valve Body For Ra2000 Units. Conforms To Ansi/Ashrae Standard 102-1983
Danfoss -- Straight Valve Body. For Ra2000 Units. Connection: 3/4" Npt.
- This fitting includes a split ring and a stainless steel insert. It's also self-flaring, which means no flaring tool is needed.
*MUST BE INSTALLED BY TRAINED PERSONNEL IN ACCORDANCE WITH NFPA 58 & 54 STATE AND LOCAL CODES
- Self-flaring design ensures versatile use
- Metal-to-metal seal for durable and reliable operations
- Features 33% more sealing surface than contemporaries
- Made of high-grade brass for enhanced strength
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Patent no. 5,988,201
- Light weight
- Proven durability
- Easy to install
- No clog vent
- 360 degree adjustable collar ring for installation flexibility
- Stainless steel concentrator which eliminates gurgling noise
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Patent no. 5,988,201
- Light weight
- Proven durability
- Easy to install
- No clog vent
- 360 degree adjustable collar ring for installation flexibility
- Stainless steel concentrator which eliminates gurgling noise
True Working Pressure to 150 psi, 3-4 Times The Venting Rate of Other Vents. Universal, One Fits-All Design. Brass Construction. Size: 1/8 in. Dimensions: 3-1/4 in. x 1 in.
- GoldTop offers a convenient, one-fits-all concept, to stock one vent for all your venting needs, between 1 and 150 psi systems
- Revolutionary patented fulcrum design offers a venting rate of 3-4 times that of other products
- Residential or commercial heating and cooling systems
- Male connection
- Higher capacity
- Four sizes available
- Spring-loaded, float type air vent
- Used in heating systems to vent air, which has accumulated due to the heating of cold water
- Easy to install
- Typical recommended locations are: on boiler top, on top of an air purger